PURE SINE WAVE ONLINE UNINTERRUPTIBLE POWER SUPPLY.
VOLMATIC UPS series congregates the essence of advanced technology and the world’s most advanced 16-bit high speed CPU control technology and 40 KHZ high frequency technology. The UPS has small volume, light weight, high efficiency,zero transfer time and pure sine wave output etc features.
This series UPS adopts the most advanced interface information operation technology, the user can see the UPS operation status directly from the LCD. With digital self-detecting and protection function, the long distance monitoring can reach the international advanced level. It is the power guard for your commercial server, PC server and peripheral, communication and internet appliance, PC and the other nicety electronic appliance.
Features:
- Digital Design.
Adopted control technology and digital design topology, UPS can be operated and maintained more conveniently. - A Real Green-environmental Protection Power.
The commercial power input factor correction technique is used. Under the Normal mode, UPS achieves real energy-saving by inputting harmonic less than 10% and frequency power factor above 99%. - Direct Current Cold Start Function.
When battery input voltage in the range of normal voltage. By pressing the ON button, UPS can start up normally. - Alarm High-low Battery Input Voltage Protection Function.
UPS alarms in case of the battery input voltage too high or too low. As the battery continuously go up or down out of the normal range, UPS will alarm and stop input or transfer to bypass mode to ensure the battery life and protect user appliance. - Communication and Monitoring Function.
Equipped with standard RS232 interface and intelligent slot. The UPS Operating and electrical parameters can be monitored through standard RS232. Through intelligent slot status interface he intelligent control can be flexibly configured according to different applications to users, for instance, stem node, network, monitoring, text message. - Output High-Low Voltage Protection.
When UPS output is greater than the output over-voltage protection point or less than the output low-voltage protection point, it will shut off inverter output to bypass and automatically alarm. After all the fault removed, users can restart the machine normally. - Output Short Circuit Protection.
When the Inverter output overloaded and short circuit, UPS will stop output and alarm and blink continuously. After the troubleshooting, it can restart normally. - Overloaded Protection Function 6 KVA to 10 KVA.
When Overload out of ranged load in certain time, UPS will turn off the inverter and switch to Bypass output by alarming. After the load back to normal, UPS automatically transfer back to inverter output. - Over-temperature Protection.
When the temperature is over high or the fan work abnormally, it will lead the main radiator temperature out of over temperature protection. At that point UPS will alarm and switch to Bypass output. Until the temperature recover normally, UPS will automatically switch to inverter output. - Intelligent Fan Speed Control Function.
According to load capability and environmental temperature, the fan speed adjustment can reduce the noise and prolong the service life.
Application:
- Data center.
- Point-of-sale.
- Router.
- Hub and other network device.
- Commercial facility.